检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
出 处:《四川化工》2013年第1期22-24,共3页Sichuan Chemical Industry
摘 要:实验使用钛基二氧化铅电极为阳极,泡沫镍作阴极对模拟硝基苯废水,研究了不同因素对硝基苯去除率的影响。并通过单因素实验分析确定了最佳反应条件:硝基苯浓度为123mg/L,辅助电介质Na2SO4浓度为7.5g/L,FeSO4浓度为0.45g/L,电解电压为18V,电解时间为80min,极板间距为4cm。在此条件下去除率可达到90%。This experiment of degradation of nitrobenzene has been taken in the self-made device, using the Ti-SnO2 electrode as anode. The research mainly study on the influence of each factor upon the nitroben- zene removal rate and select the best operating conditions to deal with the wastewater with experiments on single factors. The best electrolysis conditions are as follows: the concentration of nitrobenzene was 123mg L-~ , the concentration of Na2SO4 was 7. 5g L-1, the concentration of FeSO4 was 0. 45g L-1, electrolysis voltage was 18V, electrolysis time was 80min, and the discharge gap is 4cm. Under this condition, the re- moval rate of nitrobenzene reached 90M.
分 类 号:X703[环境科学与工程—环境工程]
正在载入数据...