检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
机构地区:[1]浙江省电力公司电力科学研究院,浙江杭州310014 [2]浙江省电力设计院,浙江杭州310014
出 处:《电力电容器与无功补偿》2013年第1期56-60,共5页Power Capacitor & Reactive Power Compensation
摘 要:熔断特性是熔断器重要特性,熔断特性试验方法对准确反映熔断器熔断特性影响较大,本文以熔断器熔断特性常规试验回路为基础,分析了熔体在熔断过程中热态电阻变化特点,通过调节试验回路参数,改进了熔断器熔断特性常规试验方法,并进行了试验验证,为准确得到熔断器熔断特性提供了有效手段。The fusing characteristics are the important characteristics of fuse and the test methods of fusing characteristics have great effect in accurately reflecting the fusing characteristics of fuse. In this paper, the conventional test circuit for the fusing characteristics of fuse is taken as the base to analyze the variation of thermal resistance of fuse, the conventional test method of using characteris- tics of fuse is improved through adjusting ratings of the test and test verification is conducted, which provides effective means to obtain accurately the fusina characteristics of the fll,qe_