浸没式方型超滤膜装置处理沉后水的中试研究  被引量:1

Pilot research on treatment of settled water by submerged square ultrafiltration membrane

在线阅读下载全文

作  者:张建明 李亮 李星[2] 

机构地区:[1]中国市政工程中南设计研究总院,湖北武汉430010 [2]北京工业大学北京市水质科学与水环境恢复工程重点实验室,北京100024

出  处:《供水技术》2013年第1期14-17,共4页Water Technology

基  金:国家水体污染控制与治理科技重大专项(2008ZX07421-002;2008ZX07422-005);国家"十一五"科技支撑计划项目(2006BAJ08B06);北京市自然科学基金资助项目(8092005)

摘  要:以沉后水为原水,研究了方型超滤膜装置的影响因素和处理效果。结果表明,跨膜压差和温度均对膜通量产生影响;随着累计过滤水量的增加,跨膜压差增大;超滤膜组件对浊度的去除效果很好,出水浊度在0.007~0.12 NTU,且不受原水水质的影响;超滤膜组件对有机物的去除效果较差,CODMn去除率不足14%。The Influencing factors and treatment effect of square uhrafihration membrane were researched taking the settled water as raw water. The results showed that transmembrane pressure (TMP) and temperature had influence on the membrane flux. TMP increased along with the increase of cumulative throughflow. Uhrafiltration membrane module had good effect on turbidity removal, the outflow turbidity was 0. 007 to 0.12 NTU, and raw water quality had no influence on it. However it had poor effect on organics removal, the removal rates of CODMn were less than 14%.

关 键 词:沉后水 浸没式超滤膜 膜通量 浊度 有机物 