检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:毛容妹[1] 谭智毅[1] 梁炜峰[1] 徐晓霞[1] 蔡清平[1] 张海峰[1]
出 处:《检验检疫学刊》2012年第6期14-17,共4页Journal of Inspection and Quarantine
基 金:广东出入境检验检疫局科研项目(2011GDK51)
摘 要:分别采用紫外荧光法及微库仑法测定标准样品及生物柴油的总硫含量,并对两种方法在回收率、准确度及精密度等方面进行对比分析,分析结果表明两者均满足标准检测要求,但紫外荧光法在准确度及精密度上优于微库仑法,且紫外荧光法更环保,更高效。With the development of the Petroleum and Chemical industry,more attention was paid to environmental protection,such as the limitation of the sulfur content of petroleum products and some organic compounds.Determining the sulfur content of Standard samples and Biodiesel by UV fluorescence method and microcoulometry was proposed in the paper.The recovery,accuracy and precision of the UV fluorescence method were compared with the microcoulometry.The Analysis results show that both of them met the requirements of standards,but UV fluorescence was better than microcoulometry in the accuracy and precision,and UV fluorescence method was more environmental protection,more efficient.
分 类 号:TE626.24[石油与天然气工程—油气加工工程]
正在载入数据...