机构地区:[1]甘肃省电力公司电力科学研究院,甘肃兰州730050
出 处:《工矿自动化》2013年第2期80-83,共4页Journal Of Mine Automation
摘 要:针对某地区750kV输变电系统存在运行电压偏高的问题,提出了一种将高漏抗变压器式分级可控高抗SCSR应用于该750kV输变电系统的设计方案;分析了SCSR的工作原理,采用电磁暂态仿真软件建立了系统仿真模型,分别仿真了系统在正常状态和故障状态下SCSR投入时抑制工频过电压和潜供电流及容量调节的效果。仿真结果表明,SCSR可有效降低该750kV输变电系统的稳态运行电压,提高系统稳定性。In view of problem of higher running voltage in 750 kV power transmission and transformation system of an Area,the paper proposed a design scheme of applying SCSR of high-leakage inductance transformer into the 750 kV system.It analyzed working principle of SCSR,used electromagnetic transient simulation software to build simulation model of the 750 kV system,and respectively simulated effects of inhibiting of power frequency over-voltage and secondary arc current and capacity adjustment of SCSR under normal state and fault state of the 750 kV system.The simulation results showed that SCSR can effectively reduce steady running voltage and improve stability of the 750 kV system.