摘  要:指出了环境空气中的NO2作为强制性监测污染物,仪器必须对其浓度进行快速、准确的监测。而仪器故障情况的有效处理有利于提高数据准确率和有效获取率。选用TE 42I氮氧化物分析仪作为监测仪,并对其在监测过程中出现的故障情况进行了判断处理和归纳总结,为同行提供经验借鉴。NO2 in the ambient air is a mandatory monitoring pollutant,thus the monitoring equipment must make a rapid and accurate monitoring of the NO2 concentration.The efficient processing for the equipment fault conditions is conducive to improving the accuracy of the data and obtaining the effective rate.Selecting TE 42Initrogen oxides analyzer as a monitoring instrument,this article processes the failure conditions which occur in the monitoring process and makes a summary,so as to provide experience and reference for counterparts.