村镇住宅基础隔震效果分析  被引量:1

Analysis of the Shock-isolation Effect of Rural Residential House

在线阅读下载全文

作  者:李黎[1] 王宗华[1] 李天[2] 郑伟花[1] 

机构地区:[1]南阳师范学院土木建筑工程学院,河南南阳473061 [2]郑州大学土木工程学院,河南郑州450001

出  处:《郑州大学学报(工学版)》2013年第1期10-13,共4页Journal of Zhengzhou University(Engineering Science)

基  金:河南省科技攻关计划资助重点项目(112102310516);南阳师院校级专项项目(ZX2009002)

摘  要:以中原地区出现最多的一类村镇住宅为例,进行标准化、统一化的隔震设计,探索实践隔震设计全流程设计方法,形成标准化的设计选用表,并且对村镇住宅基础隔震效果进行了分析.结果表明:对于6层以下的村镇住宅建筑结构,随着住宅层数的增加及住宅平面总长度的变大,隔震效果大体上逐渐增强,但变化逐渐趋于平缓.Standardized design of isolated structure is given based on the kind of rural residential house appea-ring most in Zhongyuan area, and shock-isolation design method in practical application is sought. The stand-ardized design tables are formed, and the shock-isolation effect is contrasted, the analysis suggests that: for the village residential building structure which is less than six layers, with the house layer or the total length of the residential flat increases, isolation effect is increased gradually, but the development is slowing down.

关 键 词:村镇住宅 隔震 叠层橡胶支座 标准化 隔震效果 