樊家站污水腐蚀超标原因分析及控制措施研究  被引量:3

Research on the Reason and Control Measures of Over-standard Corrosion Induced by Sewage in Fanjia Recycled Water Station

在线阅读下载全文

作  者:汪刚跃[1] 张守献[1] 徐鹏[1] 王刚[1] 徐闯[1] 汪卫东[1] 庄新峰[2] 

机构地区:[1]中石化胜利油田分公司采油工艺研究院,山东东营257000 [2]中石化胜利油田分公司纯梁采油厂,山东博兴256504

出  处:《石油天然气学报》2013年第2期146-148,1,共3页Journal of Oil and Gas Technology

摘  要:针对胜利油田樊家回注污水站外输污水腐蚀速率长期超标的问题,从沿程节点开展腐蚀速率的测试,通过污水水性、腐蚀因素的分析研究,发现樊家站污水流经悬浮床后,腐蚀速率明显升高,悬浮床处理流程不合理是外输水腐蚀速率超标的主要原因。通过优化加药工艺,使腐蚀速率得到控制,现场实施后,外输水腐蚀速率从0.391mm/a降到0.087mm/a,降低77.7%。In allusion to the problem of long over-standard corrosive rate of output sewage in Fanjia Recycled Water Station of Shengli Oilfield,the corrosion rate was tested at nodes along the waterline,the property of sewage and corrosive rate were analyzed,it was found out that the corrosive rate raised significantly after it flowed through the suspension bed,and the main reason of the problem was the treatment process of suspension bed.The corrosion rate is controlled by optimizing dosing process,after it is used in the oilfield,the corrosion rate of the output sewage decreases from 0.391 mm/a to 0.087 mm/a,it is reduced by 77.7%.

关 键 词:胜利油田 樊家站 回注污水 腐蚀速率 腐蚀控制 

分 类 号:TE983[石油与天然气工程—石油机械设备]

 