电感耦合等离子体质谱法测定饮用水中15种稀土元素  被引量:17

Determination of 15 Rare Earth Elements for Drinking Water by Inductively Coupled Plasma Mass Spectrometry

在线阅读下载全文

作  者:王雅玲[1] 王霞[2] 张晓华[1] 顾海东[1] 

机构地区:[1]苏州市环境监测中心站,江苏苏州215004 [2]江苏省环境监测中心,江苏南京210036

出  处:《环境监测管理与技术》2013年第1期37-39,共3页The Administration and Technique of Environmental Monitoring

基  金:国家环境标准修订基金资助项目(HJ 942-2009);江苏省环境监测科研基金资助项目(0819)

摘  要:采用电感耦合等离子体质谱法测定饮用水中15种稀土元素,采取内标校正法,以Rh、Re、Bi为内标,结合优化仪器条件和干扰校正方程来消除干扰。15种稀土元素的方法检出限为0.000 2μg/L~0.003μg/L,混合标准溶液平行测定的RSD<6%,饮用水样品的加标回收率为98%~120%。Inductively coupled plasma mass spectrometry (ICP-MS) was applied to determine 15 rare earth elements in drinking water by using Rh,Re,Bi as internal standards and combining optimal instrument conditions with interference correction equation to interference elimination. The 15 rare earth elements method detection lim- its range from 0.000 2 μg/L to 0.003 μxg/L. The experimental results showed the method determine limits can meet for the requirement of determination. Recoveries of spiked samples were in the range of 98% - 120% andRSD was lower than 6%.

关 键 词:稀土元素 电感耦合等离子体质谱法 饮用水 

分 类 号:O657.63[理学—分析化学]

 