MSVC系统在高耗能企业电能质量治理中的运用  

Discussion on the Implication of MSCV System in Power Quality Control of Enterprise with High Energy Consumption

在线阅读下载全文

作  者:刘瑞 徐振梅[2] 

机构地区:[1]内蒙古超高压供电局,呼和浩特010080 [2]河北医科大学,石家庄050200

出  处:《电气技术》2013年第3期41-44,共4页Electrical Engineering

摘  要:通过对当前系统运行时的电能质量测试分析,结合该工况,给出合理、安全、可靠、技术先进的无功补偿及谐波治理方案。MSVC型高压动态无功补偿装置具有自动化程度高、保护完善、低耗能、高效率的特点,能实时跟随负荷变化自动跟踪,不会出现过补偿和欠补偿现象,保证高功率因数运行。A suitable reactive power compensation and harmonic treatment program with reliable safety and advanced technique is supported based on the specially appointed working condition, according to the analysis of power quality examination on the current operation system. MSVC has the characteristics of high automation, perfect protection, lower energy consumption and high efficiency, and can follow the load automatically with its timely change in case of the overcompensation and undercompensation, ensuring the performance with high power factor.

关 键 词:无功补偿 谐波 滤波 电能质量 

分 类 号:TM73[电气工程—电力系统及自动化]

 