台式计算机机箱内粉尘含铅量的检测  

Determination of Lead in Dusts Sampled from Cases of Desktop Computers

在线阅读下载全文

作  者:黄弋石[1] 丁亦青[1] 季莘[1] 李春健[1] 

机构地区:[1]南通大学公共卫生学院实验中心,江苏南通226019

出  处:《广东化工》2013年第6期21-21,33,共2页Guangdong Chemical Industry

摘  要:建立了简单的对台式计算机机箱内粉尘含铅量的检测方法。用原子吸收法,在优化的仪器工作条件下,将检测目标控制在测定铅的线性范围中,精度优良。结果表明,机箱内粉尘铅含量平均值为0.027μg,机箱外排风口的粉尘铅含量平均值为0.007μg,对其t检验,t=3.886,P<0.01,两组差别显著。可见,机箱内环境为高铅危险沾污区域。Set a simple method to collect and detect the content of lead in the powders sampled from the cases of desktop computers. Discussed various test conditions and effect factors, developed the method for determination of lead by atomic absorption spectrometry. This method acts with high sensitivity, accurateness. The results revealed, mean value of lead inside cases is 0.027 μg according to our new method comparison standard, mean value near the vents is 0.007 μg, t-test showed, t=3.886, P 〈 0.01, two groups appear significant difl'erence. Obviously, the areas in boxes are highly dangerous because of the lead powders contained.