检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:崔正英 周航宇 S.MORITA 傅炳忠 孙平 高亚东 M.GOTO 徐媛 董春凤 杨青巍
机构地区:[1]Southwestern Institute of Physics, Chengdu 610041, China [2]National Institute for Fusion Science, Toki 509-5292, Gifu, Japan
出 处:《Plasma Science and Technology》2013年第2期110-114,共5页等离子体科学和技术(英文版)
基 金:partially supported by National Natural Science Foundation of China (Nos. 10975048 and 11175061);the JSPS-NRF-NSFC A3 Foresight Program in the Field of Plasma Physics (No. 11261140328)
摘 要:A normal incidence vacuum ultraviolet (VUV) and a grazing incidence extreme ultraviolet (EUV) spectrometers have been developed for the edge and core impurity measure- ments in HL-2A tokamak. The VUV and the EUV spectrometers cover wavelength ranges of 300-3200 A and 50-500A, respectively. A spatial resolution of 2 mm has been achieved for the VUV spectrometer when a space-resolved slit 50 #m in width is used. The space-resolved slit is placed between the entrance slit and the grating of the spectrometer. The spectral resolutions of 0.15/~ for the VUV spectrometer in the wavelength coverage of the concave 1200 grooves/mm grating and of 0.22A for the EUV spectrometer at λ=200A with a flat-field laminar-type holo- graphic grating are obtained. The sensitivity of the VUV spectrometer was calibrated in situ with the plasma bremsstrahlung radiation. The experimental results from both spectrometers are presented, especially the line intensity radial profiles measured by the VUV spectrometer.A normal incidence vacuum ultraviolet (VUV) and a grazing incidence extreme ultraviolet (EUV) spectrometers have been developed for the edge and core impurity measure- ments in HL-2A tokamak. The VUV and the EUV spectrometers cover wavelength ranges of 300-3200 A and 50-500A, respectively. A spatial resolution of 2 mm has been achieved for the VUV spectrometer when a space-resolved slit 50 #m in width is used. The space-resolved slit is placed between the entrance slit and the grating of the spectrometer. The spectral resolutions of 0.15/~ for the VUV spectrometer in the wavelength coverage of the concave 1200 grooves/mm grating and of 0.22A for the EUV spectrometer at λ=200A with a flat-field laminar-type holo- graphic grating are obtained. The sensitivity of the VUV spectrometer was calibrated in situ with the plasma bremsstrahlung radiation. The experimental results from both spectrometers are presented, especially the line intensity radial profiles measured by the VUV spectrometer.
关 键 词:VUV spectra EUV spectra SPECTROMETER spatial resolution
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:3.129.23.57