检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:卢晓峰[1] 张俊英[2] 孙淑明[1] 谢舜峰[1]
机构地区:[1]汕头大学医学院第一附属医院甲状腺乳腺外科,505041 [2]汕头大学医学院附属肿瘤医院信息科,515041
出 处:《当代医学》2013年第8期74-75,共2页Contemporary Medicine
摘 要:目的探讨美蓝染色与术中B超定位在乳头溢液手术中的应用价值。方法将46例乳头溢液患者随机分为两组,分别采用美蓝染色及术中B超定位,确定病变导管后手术,并评价效果。结果美蓝组切除的腺体质量明显小于B超组,差异有统计学意义(P<0.05)。术野污染率美蓝组为13.04%(3/23),B超组为0(0/23);病灶遗漏率美蓝组为0(0/23),B超组为8.70%(2/23),两组比较,差异有统计学(P<0.05)。结论美蓝染色和术中B超定位对乳头溢液患者病灶的切除,具有安全、准确、实用等优点,两者合用可提高治疗效果。Objective To investigate the value of methylene blue staining and intraoperative B-ultrasound localization in the operation of nipple discharge.Methods 46 cases with nipple discharge were randomLy divided into methylene blue group and B-ultrasound group. The operation began when the diseased galactophores were determined, and their clinical data were analyzed.Results The weight of excisional breast in the methylene blue group were significantly less than those in the B-ultrasound group (P0.05). The incidence of operation field pollution in the methylene blue group was 13.04%(3/23),while 0(0/23)in the B-ultrasound group. And the incidence of focus omission in the methylene blue group was 0(0/23),while 8.70%(2/23) in the B-ultrasound group. It was a significantly difference (P0.05).Conclusion The methods of methylene blue staining and intraoperative B-ultrasound localization were safe, exact and practical. The treatment effect could be increased when the two methods were combined.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222