摘  要:采用催化内电解/水解酸化/接触氧化/混凝工艺处理制药废水。经催化内电解预处理后,对COD的去除率达61%,B/C值由0.1上升到0.3以上;系统对进水水质有良好的抗冲击性能,且对COD、NH3-N的平均去除率分别为89%、95%,对TP几乎能全部去除,出水水质达到《污水综合排放标准》(GB 8978—1996)的一级标准;该工艺处理费用仅为1.61元/m3。The catalyzed internal electrolysis/hydrolysis acidification/bio-contact oxidation/coagu- lation process was used for the treatment of pharmaceutical wastewater. The COD removal rate was 61% while the B/C improved from O. 1 to above 0.3 after the catalyzed internal electrolysis. The system had high resistance to influent loads, and the removal rates of COD, NH3 - N and TP were 89% , 95% and nearly 100% , respectively. The effluent quality met the first class criteria specified in the Integrated Wastewater Discharge Standard ( GB 8978 - 1996). The operation cost of the combined process was only 1.61 yuan/m3.

关 键 词:制药废水 催化内电解 水解酸化 接触氧化 混凝 

分 类 号:X787[环境科学与工程—环境工程]

 