检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:雷民[1,2] 周峰[1,2] 项琼[1,2] 肖凯[1,2] 陈松[1,2]
机构地区:[1]中国电力科学研究院 [2]国家高电压计量站,武汉430074
出 处:《供用电》2013年第2期71-75,共5页Distribution & Utilization
摘 要:比较分析了工频电压比例自校系统溯源的发展过程,提出了半绝缘互感器电压串联加法新线路,建立了110 kV工频电压比例国家计量标准装置,计量性能提升了2个准确度等级,克服了原有自校系统中主标准必须为全绝缘屏蔽型电压互感器的局限性,减少了由于屏蔽电位引入的不确定度,准确度等级更高、开放性更好,适合在省级计量机构推广应用。The paper compares and analyzes the traceable development of power frequency voltage ratio system, and proposes a traceability method based on semi-insulating voltage series summation. The new generation national ll0kV Power Frequency Voltage Ratio Standard Apparatus capable of boosting accuracy by two grades is then established. Unlike the old system, in which the main standard must be of fully-insulating, the apparatus reduces the uncertainty caused by the shielding potential. With higher accuracy and greater openness, this new system is suitable to be widely applied in provincial metrology institutes.
关 键 词:工频电压比例标准 自校系统 半绝缘电压串联加法 杂散电容
分 类 号:TM933[电气工程—电力电子与电力传动]