作 者:王弋嘉[1] 张崇磊[1] 王蓉[1] 朱思伟[2] 袁小聪[1]
机构地区:[1]南开大学信息技术科学学院现代光学研究所,天津300071 [2]南开大学人民医院,天津300121
出 处:《光学精密工程》2013年第3期672-679,共8页Optics and Precision Engineering
基 金:国家自然科学基金重点项目(No.61036013)
摘 要:分析了影响相位调制的表面等离子体共振(SPR)传感器灵敏度及动态范围的各种因素。搭建了差分干涉SPR相位检测系统,使用matlab软件模拟了若干因素对该类传感器的灵敏度和动态范围的影响,并使用3种厚度的金膜进行了实验验证,同时实时测量了牛血清白蛋白与其抗体之间的反应过程。结果显示,入射角度对于灵敏度和动态范围没有影响,而入射光波长、所选金属的介电常数和金膜厚度这3个因素是起作用的。这3个因素中,金膜厚度是比较重要且最易调节的一个。选定金膜后,通过调节入射角和反应物浓度,将抗原抗体反应导致的相位变化限制在系统的线性范围内进行了实时检测。结果表明,对于波长为633nm的光源,在测量牛血清白蛋白与其抗体之间的反应过程中,兼顾灵敏度和动态范围的最优金膜厚度为48nm,此时动态范围为0.013 6RIU,灵敏度为6.67×10-7 RIU/0.01°。The sensitivity and dynamic range are main performance parameters of a Surface Plasmon Resonance(SPR) biosensor with phase modulation. In this paper, the main effect factors on sensitivi- ty and dynamic range of the sensor were analyzed, and the influence of nonlinear change of phase difference on the results of real-time monitoring biological reaction was analyzed. A high resolution SPR system based on a Mach-Zehnder configuration was set up. The phase difference curves of a se- ries gold membrane thicknesses and incident angles were simulated by matlab software, and the effect of several factors on the resolution and dynamic range were evaluated. In addition, the real-time moni- toring of binding reaction between Bovine Serum Albumin(BSA) and BSA antibodies was also demon- strated. Obtaineel results show that the influence of membrane thickness is significant and nonlinear, but the incident angle shows little effect on the resolution and dynamic range. The influence of narrow dynamic range on biology reaction measurement can be minimized by optimizing some parameters, such as membrane thickness, incident angle and reactants concentration. Experimental results show that the sensitivity and dynamic range can be optimized by adjusting gold membrane thicknesses. This paper analyzed several influence factors of the sensitivity and dynamic range of phase modulation SPR biosensors. For a light source with 633 nm wavelength, the most optimal membrane thickness is 48 nm when the reaction between BSA and its antibody is measured. In this situation, the dynamic range is 0. 013 6RIU and the sensitivity is 6.67 X 10-TRIU/0.01.
关 键 词:生物传感器 表面等离子体共振传感器 相位调制 动态范围 灵敏度
分 类 号:TP212.3[自动化与计算机技术—检测技术与自动化装置]
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.3