发生在两台135MW发电机上的同类定子故障  

Same Kinds of Stator Failure Happened in Two Sets of 135 MW Generator

在线阅读下载全文

作  者:梁保华 

机构地区:[1]连州发电厂,513400

出  处:《电机技术》2013年第1期57-61,共5页Electrical Machinery Technology

摘  要:介绍了连州发电厂3、4号发电机定子铁心端部阶梯齿断齿以及端部线棒受损的情况。分析了故障现象后,确定定子故障原因主要是由于铁心端部松动、铁心硅钢片表面受损等隐患引起的。针对起因对定子铁心进行了断齿修复和紧固,对受损线棒进行了更换和修理,跟踪各发电机修复后运行状况,结果良好。Both the broken of the ladder-shaped teeth and damage of the coil bar of the stator happened in the No.3 and 4 generators in the Lianzhou power plant were introduced. After analyzing the failure phenomenon, the cause of the failure resulted from such hidden factors as the core-loosing and insulation layer damage on the surface of silicon steel sheet was confirmed. The Teeth-broken in the ladder-shaped teeth in the stator was repaired, core-loosing was retightened and damaged coil bar was replaced punctually against the cause. It was found that the repaired generator operated normally after long-term following up.

关 键 词:发电机 定子铁心 松动 断齿 绝缘损伤 故障处理 