摘 要:运用FLUENT软件模拟研究600 MW四角切圆煤粉锅炉在过量空气系数分别为1.1、1.2和1.3等3种工况的燃烧特性。研究结果表明,随着过量空气系数增加,主燃烧区的气流速度明显加快,温度逐渐升高,O2浓度升高,CO浓度明显降低。另外,分析了不同过量空气系数对炉膛出口平均速度、烟温以及对NOx生成的影响规律,为锅炉的设计、运行和改造提供了一定依据。FLUENT software has been employed to investigate combustion characteristics in the tangentially fired furnace of a 600 MW pulverized coal boiler at different excess air ratios of 1.1, 1.2 and 1.3. The results show that with the increasing of excess air ratio, air velocity and temperature in primary combustion zone increased; and CO concentration decreased due to the increasing of 02 concentration. Furthermore, the numerical simulation for impact of excess air ratio on average velocity, gas temperature and NOx formation at the furnace outlet is conducive to the boiler design, operation and transformation.