圆形断面净化空调机组相关问题的探讨  被引量:2

Discussion on air handling unit with circular section for cleaning air system

在线阅读下载全文

作  者:初春玲 周俊彦 

机构地区:[1]中石化上海工程有限公司 [2]上海亚新工程顾问有限公司

出  处:《暖通空调》2013年第3期99-103,共5页Heating Ventilating & Air Conditioning

摘  要:建立了数学模型,对比分析了圆形断面和正方形断面空调机组的沿程阻力,表冷器、过滤器的断面风速和阻力,机组的隔声性能。结果表明,在相同条件下,圆形断面空调机组的沿程阻力可以降低11%,但是以多占用机房面积为代价的;表冷器、过滤器阻力明显增加;机组壁板的隔声效果较差。Establishes the mathematical model and compares the frictional resistance, the sectional air speed and resistance of surface air coolers and filters, and sound insulation performance, between circular section and square section AHUs. The results show that the frictional resistance of a circular section AHU is 11% lower than that of a square section AHU at the costs of increased space requirement for the plant room, obviously increased resistance of the surface air coolers and filters and poorer sound insulation effects.

关 键 词:圆形断面空调机组 沿程阻力 表冷器 过滤器 隔声 

分 类 号:TU831[建筑科学—供热、供燃气、通风及空调工程]

 