检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:冯壮壮[1] 王海东[2] 于建[1] 高康乐[2] 梁文艳[1]
机构地区:[1]北京林业大学环境科学与工程学院,北京100083 [2]中冶集团建筑研究总院,北京100088
出 处:《工业水处理》2013年第4期61-64,共4页Industrial Water Treatment
摘 要:采用钌钛网为阳极、钛网为阴极的电催化氧化装置深度处理焦化废水,研究了电流密度、极板数量、反应器结构、污水流态及流速对COD去除及处理能耗的影响。结果表明,在电极板4对、电流密度100 A/m2、推流循环流态、流速50 mL/min、处理时间120 min的条件下,电能利用率最高,装置对污水COD的去除率达到58.8%,COD去除能耗为78.6 W.h/g。The electro-catalytic oxidation equipment has used Ti/RuO2 mesh as anode, and titanium mesh as cathode for the advanced treatment of coking wastewater. The effects of current density,the number of polar plates, reactor structure ,waste-water flow state and flow velocity on COD removing rate and energy consumption are studied. The results show that when four pairs of polar plates are used ,the current density is 100 A/m2,plug-flow circulation flow state ,the flow velocity is 50 mL/min ,and treatment time is 120 min ,the electrical energy utilization is the the COD removing rate reaches 58.8% and the energy consumption of COD removal is 78.6 W.h/g.