检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:钟晓[1] 王启山[1] 何凤华[2] 李思思[1] 岳尚超[1]
机构地区:[1]南开大学环境科学与工程学院,天津300071 [2]天津泰达自来水公司,天津300457
出 处:《工业水处理》2013年第4期69-71,共3页Industrial Water Treatment
摘 要:以滦河水为处理对象,对自来水厂预氯化—V型滤池+氯消毒工艺各处理单元的出水进行了检测。结果表明,原水经过预氯化处理后,对藻类和叶绿素a的平均去除率分别为31.37%和57.29%;整套工艺对藻类和叶绿素a的平均去除率分别可达78.91%和99.34%。此外,预氯化可有效降低浊度,但对UV254、DOC的去除效果不明显。预氯化后会生成三卤甲烷和卤乙酸,但后续工艺对其有一定的去除作用。Water in the Luan River has been treated. The effluent from the treating units, such as prechlonnatlon-V-type filter+disinfection by chlorine in water works, are detected. The results show that after the raw water has been treated by prechlorination,the average removing rates of the algae and chlorophyll-a are 31.37% and 57.29% ,respectively. The average removing rates of the algae and chlorophyll-a can reach 78.91% and 99.34%, respectively by the whole set of technology. Besides ,preehlorination can reduce the turbidity efficiently, but the removing effect by UV254 and DOC are not remarkable. Haloform and haloacetic acid will generate after prechlorination, but it has certain removing effect by the subsequent process.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.27