冬季工况下地埋管地源热泵系统中大地的自调节能力分析  被引量:1

Analysis of the Ground Adjustment Ability of the Ground-Source Heat Pump Systems in Winter

在线阅读下载全文

作  者:王勇[1] 杜红梅[1] 罗敏[1] 

机构地区:[1]重庆大学三峡库区生态环境教育部重点实验室,重庆400045

出  处:《土木建筑与环境工程》2013年第2期92-99,共8页Journal of Civil,Architectural & Environment Engineering

基  金:重庆市科委自然科学基金(CSTC,2010BB4235)

摘  要:以夏热冬冷地区某实际地埋管地源热泵系统为分析对象,对夏季采用冷却塔供冷而仅冬季采用地埋管和消防水池联合供热的系统运行参数进行了6a测试。建立了地埋管三维管群模型,通过数值计算方法对地埋管周围岩土的温度分布进行了热平衡分析和计算。通过测试数据与理论计算结果进行对比分析,得到了影响大地自调节能力的影响因素。Based on an actual ground-source heat pump system in hot summer and cold winter area,the system operation parameters were tested for 6 years under the state of using cooling tower for cooling in summer but the ground heat exchanger and fire pool for heating in winter.A three-dimensional(3D) tube-group model was established,and the thermal balance analysis and calculation of the ground temperature distribution around the ground heat exchanger were conducted by the numerical calculation.According to the comparison between the test data and the theoretical results,the influencing factors of the ground adjustment ability were obtained.

关 键 词:地源热泵 大地自调节能力 热平衡 三维模型 

分 类 号:TU831[建筑科学—供热、供燃气、通风及空调工程]

 