检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:汤志超[1] 籍庆余[1] 刘志敏[1] 魏虹[1] 张国彬[1] 刘靖[1] 杨瑞[1] 刘霞[1] 杨丹[1]
机构地区:[1]包头医学院第二附属医院CT室,内蒙古014030
出 处:《放射学实践》2013年第4期405-408,共4页Radiologic Practice
基 金:包头市医药卫生基金项目(2011S2012-08-04)
摘 要:目的:探讨4D多时相及心电编辑后处理方法对CT冠状动脉成像图像质量的影响。方法:采用128层螺旋CT对41例检查过程中出现心律失常、屏气不足的患者进行扫描,利用4D多时相和/或心电编辑对原始图像数据进行重组,分析不同种类心律失常患者图像在利用不同图像重组方法前后图像质量的差异。结果:出现心律失常的35例患者中:窦性心律不齐17例、房性心律不齐10例、室性心律不齐8例,35例患者在未行4D多时相和心电编辑重组处理前图像质量均≤3分且无法达到临床诊断需要,采用4D多时相和/或心电编辑重组方法后图像质量明显增加,差异有统计学意义(F=68.453,P<0.05),且同时采用4D多时相和心电编辑重组方法的的图像质量最高。6例屏气不足的患者经4D多时相重组后其图像质量均≥4分。结论:128层螺旋CT特有的4D多时相及心电编辑重组方法可明显提高扫描中出现心律失常或屏气不足的受检者的冠状动脉成像图像质量,提高检查成功率,降低检查重复率。Objective:To study the effect of 4D multi-temporal phase reconstruction and ECG editing post-processing technique in the image quality of coronary CT arteriography (CTA). Methods: Coronary CTA using a 128-slice spiral CT system was performed in 41 cases,cardiac arrhythrnia and breath-hold deficient appeared during examination. Post-process- ing of the raw data using 4D multi-temporal phase and/or ECG editing reconstruction techniques were done, the image quali- ties of patients with various kinds of arrhythmia before and after using different image reconstruction methods were ana- lyzed. Results:Of the 35 cases with arrhythmia,there were sinus arrhythmia (17 cases),atrial arrhythmias (10 cases),and ventricular arrhythmia (8 cases). The score of evaluating image quality in these 35 cases with arrhythmia before ECG edi- ting and 4D multi-temporal phase reconstruction were ≤3 ,which could not meet the requirement of clinical diagnosis. The image quality was obviously improved after 4D multi-temporal phase and/or ECG editing reconstruction, with significant statistic difference (F= 68. 453, P〈0.05). The image quality of 4D multi-temporal phase reconstruction in combination with ECG editing simultaneously was the best. The image quality of 6 cases with breath-hold deficient and post-processed by 4D multi-temporal reconstruction had the score ≥4 points. Conclusion:The image quality of coronary CTA in arrhythmia or breath-holding deficient subjects could be significantly improved by using ECG-editing and 4D multi-temporal phase recon- struction installed in 128-slice spiral CT system,the success rate of examination increased and the repetition rate reduced.
关 键 词:体层摄影术 X线计算机 4D多时相重组 冠状动脉成像图像质量
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.222