基于有限元程序的电厂冷却塔塔内结构内力整体分析  被引量:2

Research on the Integer Structure Internal Force of one Cooling Tower with the Finite Element Method

在线阅读下载全文

作  者:黄刚[1] 陈朝[1] 张权[1] 黄灵武[1] 

机构地区:[1]国家核电技术公司国核电力规划设计研究院,北京100095

出  处:《特种结构》2013年第1期57-60,共4页Special Structures

基  金:科技部重大科技项目(2008ZX060042001)

摘  要:在大型钢筋混凝土冷却塔结构设计方面,由于塔壳受外面风荷载、自重等综合作用,以往研究主要集中于冷却塔壳体及其相关结构方面,而没有对相关的塔内结构进行有效的分析。本文结合典型工程的塔内布置、地质及地震条件,利用有限元分析方法对塔内结构进行了整体性分析,并对比静力计算结果进行了验证,证明了塔内结构整体分析计算结果的有效性。In the field of structure design of natural draft cooling tower, foregone research frequently pay attention to the thin shell structure ,ring beam and shell supports as these structures are related with the wind load, dead weight, and pay little attention to the internal and hydraulic structure by contraries. This paper pay attention to the research on the integer internal and hydraulic structure of the cooling tower with the finite element method, combined with the layout and the engineering geologic condition, earthquake condition. Then the results of the calculation are validated and analyzed, which could conclude that the results of the calculation are trusty.

关 键 词:冷却塔 塔内结构 有限元方法 

分 类 号:TU375[建筑科学—结构工程]

 