检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:费科[1] 吴在军[1] 朱皓斌[1] 杨文燮[1]
出 处:《电气传动》2013年第4期41-44,共4页Electric Drive
基 金:国家自然科学基金资助项目(50807008)
摘 要:针对同时包含非线性负荷和线性负荷的微网,将分布式电源(DG)分为只带线性负载的和带有非线性负载的两类。对于带有非线性负载的DG,提出了一种基于dq坐标瞬时功率理论的谐波电流补偿算法,通过测得的微网内非线性负载谐波电流和逆变器额定功率输出,计算逆变器的参考电流,并采用滞环控制对逆变器进行控制;对只带有线性负载的DG采用传统下垂控制方法。用此种方法实现了该微网系统并网和孤岛模式的平滑切换和两种模式下的谐波抑制,并用Matlab/Simulink验证了该控制策略的有效性。Aimed at the microgrid that contains both non- linear load and linear load, the DGs were divided into two categories.One only contains linear load,the other contains non-linear load.For the DG with non-linear load, a harmonic current compensation algorithm was presented based on dq axis theory of instantaneous power.The reference current of the inverter was calculated through the measured harmonic current and the rated output power of the inverter.And the inverter is controlled by hysteresis control method. And the DG only with linear load is controlled by traditional droop control method.Through this method, the microgrid can be switched smoothly between the modes of grid- connected and island.And the harmonic current can be filtered in both two modes. The effectiveness of the control strategy is verified by Matlab/Simulink.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.3