摘 要:本文针对1栋办公建筑和1栋住宅建筑进行了土壤源热泵系统地埋管运行温度工况的监测,分析了2种建筑类型地埋管的运行特性。分析结果显示,办公建筑的地埋管温度工况较住宅建筑更为稳定。另外,通过对实际运行数据的分析,给出了有关土壤源热泵系统设计和运行管理的建议。In this paper,the operational temperatures of the ground heat exchanger (GHE) of ground source heat pump system for an office building and a residential building were monitored respectively, and the operational characteristics of GHE for both types of buildings were analyzed. The results indicated that the operational temperature of GHE of the office building was more stable than that of the residential building. In addition,through the analysis of the operational data,the suggestions for design and operational management of ground source heat pump system were proposed.