双柱串联-超高效液相色谱-质谱法检测水中的4种胺类物质  被引量:17

Simultaneous Determination of Acrylamide,Caprolactam,Benzidine and Aniline by Ultra Performance Liquid Chromatography Tandem Mass Spectrometry with Two Coupled Columns

在线阅读下载全文

作  者:朱丽波[1] 徐能斌[1] 冯加永[1] 钱飞中[1] 陈钟佺[1] 

机构地区:[1]宁波市环境监测中心,宁波315012

出  处:《分析化学》2013年第4期594-597,共4页Chinese Journal of Analytical Chemistry

基  金:国家水体污染控制与治理重大专项(No.2009ZX070527-001-005);宁波市自然科学基金(No.2011A610087)资助

摘  要:采用两根液相色谱柱串联的方式,建立了超高效液相色谱串联质谱(UPLC-MS/MS)同时检测丙烯酰胺、己内酰胺、联苯胺和苯胺的方法。地表水样品经过0.2%m滤膜过滤之后即可直接进样,回收率达89.9%~111.5%;废水样品通过固相萃取(SPE)净化,回收率达80.9%~99.8%,本方法对丙烯酰胺、己内酰胺、联苯胺和苯胺的检出限分别0.5,3.0,0.2和0.1%g/L。An UPLC-MS/MS method with two coupled columns was developed for the simultaneous determination of acrylamide,caprolactam,aniline and benzidine in water samples.The drinking water samples could be injected into the UPLC system just after being filtered through a 0.2 membrane.The recoveries were in the range of 89.9%-111.5%.The waste water samples were purified by solid phase extraction(SPE),and then were analyzed.The recoveries in waste water were 80.9%-99.8%.The limits of detection(LOD) of acrylamide,caprolactam,benzidine and aniline were 0.5,3.0,0.2 and 0.1 L,respectively.

关 键 词:丙烯酰胺 己内酰胺 联苯胺 苯胺 双柱串联 超高效液相色谱-质谱法 

分 类 号:X832[环境科学与工程—环境工程]

 