特高压串补电容器内熔丝试验研究  被引量:13

Research on Test of Internal Fuse for UHV Series Compensation Capacitor

在线阅读下载全文

作  者:蔡重凯[1,2] 陈晓宇[1,2] 金百荣[1,2] 李电[1,2] 洪金琪 李云飞[1] 

机构地区:[1]绍兴电力局,浙江绍兴312000 [2]电力工业无功补偿成套装置质量检验测试中心,浙江绍兴312000

出  处:《电力电容器与无功补偿》2013年第2期28-33,共6页Power Capacitor & Reactive Power Compensation

摘  要:国内首次采用在0.5UN交流电源下,对晋东南—南阳—荆州特高压扩建工程串补装置用串联电容器内熔丝进行检测。本文介绍了特高压串补电容器内熔丝隔离试验情况,对特高压内熔丝的熔断特性进行分析,并对电容器的内熔丝选型配置开展进一步研究,根据试验情况和研究结果,提出一些想法和建议。In china, the detection of series compensation device by the use of internal fuse of series compensation for South eastern Shanxi--Nanyang--Jingzhou UHV project expansion project under AC power supply of 0.5 UN is firstly used. In this paper, the isolation test of internal fuse of UHV series compensation capacitor is introduced, the fuse characteristics of the UHV internal fuse is analyzed; the selection and configuration of capacitor internal fuse are studied further. Some ideas and suggestions are made in accordance with the test and study results.

关 键 词:特高压 串补装置 串联电容器 试验研究 

分 类 号:TM531.4[电气工程—电器]

 