A chemometric method to identify selective ion for resolution of overlapping gas chromatography-mass spectrometry signal  

A chemometric method to identify selective ion for resolution of overlapping gas chromatography-mass spectrometry signal

在线阅读下载全文

作  者:MEI Zhen DU GuoRong CAI WenSheng SHAO XueGuang 

机构地区:[1]Research Center for Analytical Sciences, College of Chemistry, Nankai University

出  处:《Science China Chemistry》2013年第5期656-663,共8页中国科学(化学英文版)

基  金:financially supported by the National Natural Science Foundation of China (21175074)

摘  要:A chemometric method to determine selective ion by using non-negative immune algorithm (NNIA) was proposed. In the method, the mutual projections of the chromatographic profiles at different m/z channel are calculated using NNIA. Suppose a GC-MS data with m retention time points and n mass channels, the projections of the GC-MS data onto a chromatographic profile at a mass channel will form a mass spectrum of ln vector. If the chromatographic profile at a selective mass channel is used, the extracted mass spectrum will be a correct one. Therefore, by comparing the extracted mass spectrum with a reference spectrum, the selective ion can be identified, and the corresponding chromatographic profile can be obtained at the same time. GC-MS data of 40-pesticide mixture was investigated by the method. The results show that both the mass spectral and the chromatographic information of the interested components can be extracted from the overlapping signals, except for the special cases of isomeric components with very similar mass spectra.A chemometric method to determine selective ion by using non-negative immune algorithm (NNIA) was proposed. In the method, the mutual projections of the chromatographic profiles at different m/z channel are calculated using NNIA. Suppose a GC-MS data with m retention time points and n mass channels, the projections of the GC-MS data onto a chromatographic profile at a mass channel will form a mass spectrum of 1 n vector. If the chromatographic profile at a selective mass channel is used, the extracted mass spectrum will be a correct one. Therefore, by comparing the extracted mass spectrum with a reference spectrum, the selective ion can be identified, and the corresponding chromatographic profile can be obtained at the same time. GC-MS data of 40-pesticide mixture was investigated by the method. The results show that both the mass spectral and the chromatographic information of the interested components can be extracted from the overlapping signals, except for the special cases of isomeric components with very similar mass spectra.

关 键 词:gas chromatography-mass spectrometry selective ion detection immune algorithm CHEMOMETRICS resolution of overlapping peak 

分 类 号:O657.63[理学—分析化学]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象