基于振动法的抗疲劳断裂水泥稳定碎石强度标准  被引量:25

Strength Standard of Anti Fatigue-Fracture Cement Stabilized Macadam Based on Vibration Testing Method

在线阅读下载全文

作  者:李頔[1,2] 蒋应军[1] 任皎龙[3] 

机构地区:[1]长安大学特殊地区公路工程教育部重点实验室,陕西西安710064 [2]交通铺面材料教育部工程研究中心,陕西西安710064 [3]东南大学交通学院,江苏南京210096

出  处:《建筑材料学报》2013年第2期276-283,共8页Journal of Building Materials

基  金:中央高校基本科研业务费专项资金资助项目(CHD2011ZY007);教育部新世纪优秀人才支持计划项目(NCET-08-0749)

摘  要:以水泥稳定碎石基层施工期和运营期在荷载作用下不发生疲劳破坏所需材料最小强度为准则,研究了水泥稳定碎石力学强度特性、疲劳特性及施工期与运营期水泥稳定碎石基层荷载响应,提出了抗疲劳断裂的水泥稳定碎石强度标准.结果表明:为防止基层在施工车辆荷载作用下发生极限断裂破坏,水泥稳定石灰岩碎石基层必须养护7d后,且其劈裂强度达到0.55MPa以上,方可进行下结构层施工;为防止设计年限内基层在施工车辆和运营车辆反复作用下产生疲劳断裂,水泥稳定石灰岩碎石7d劈裂强度不应小于0.70MPa.为了便于应用,结合抗压强度和劈裂强度的关系,提出水泥稳定石灰岩碎石7d抗压强度不应小于7.0MPa.Cement stabilized limestone macadam is taken as object, researches on the mechanical strength characteristics and fatigue property, the load response of cement stabilized macadam during the construction and operation period are conducted. The standard of strength for fatigue fracture of the cement stabilized macadam was proposed. The researches show that in order to prevent the ultimate damage caused by construction vehicle load, the con- struction of next structure layer should be conducted until the curing age of cement stabilized limestone macadam is no less "than 7 d and the splitting strength is no less than 0. 55 MPa; to prevent the fatigue damage under repeated load effect of the construction and operation vehicle during the designed usage, the 7 d splitting strength should be no less than 0.70 MPa. In order to facilitate application, in consideration of the relationship between compressive strength and splitting strength, it is proposed that the 7 d compressive strength of cement stabilized limestone macadam should be no less than 7.0 MPa.

关 键 词:道路工程 水泥稳定碎石 振动法 抗疲劳断裂 强度标准 

分 类 号:U416.212[交通运输工程—道路与铁道工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象