摘  要:目的建立同时检测人血浆中3种抗结核药物异烟肼、乙胺丁醇和吡嗪酰胺浓度的LC-MS/MS方法,用于肺结核患者及临床试验中三药血药浓度的测定。方法以对乙酰氨基酚为内标,血浆样品经乙腈沉淀蛋白等处理后检测。采用Agilent ZORBAX SB-Aq色谱柱(2.1mm×100mm,3.5μm)为分析柱,ZORBAX SB-Aq柱(2.1mm×12.5mm,5μm)为保护柱,以乙腈-5mmol·L^-1甲酸铵水溶液(含0.1%甲酸)(8:92,v/v)为流动相,使用电喷雾离子源(ESI),以正离子多反应监测(MRM)方式进行检测,异烟肼m/z138.2→121.0,乙胺丁醇m/Z205.2→116.1,吡嗪酰胺m/z 124.1→81.1,对乙酰氨基酚m/z 152.0→110.0。分析时间为5min。结果血浆中内源性物质对测定无干扰,异烟肼线性范围为0.1~6.0μg·ML^-1,定量下限(LLOQ)为0.1μg·ML^-1,乙胺丁醇线性范围为0.1~5.0μg·ML^-1,定量下限(LLOQ)为0.1μg·ML^-1,吡嗪酰胺线性范围为1.0~50.0μg·ML^-1,定量下限(LLOQ)为1.0μg·ML^-1。日内、日间精密度(RSD)均小于10%,准确率为90.4%~108.7%。结论本方法特异性强,灵敏度高,测定结果可靠,适用于临床血浆样品的高通量分析。Objective To establish an LC-MS/MS method for the determination of isoniazid, ethambutol, pyrazinamide in human plasma and to assay the biological samples from clinical trials. Methods 4-acetamidophenol was used as internal standard. The protein of plasma samples were precipitated with acetonitrile. The supernatant was separated on an Agilent ZORBAX SB-Aq column(2.1 mm× 100 mm, 3.5 1μ m) guarded by a ZORBAX SB-Aq column(2.1 mm× 12.5 mm, 5 μ m). The mobile phase consisted of acetonitrile -5 mmol · L^-1 ammonium formate, 0.1% formic acid solution (8:92, v/v). Electrospray ionization (ESI) source was applied and operated in the positive multiple reaction monitoring (MRM) mode. The transition of m/z was138.2 →121.0 for isoniazid, 205.2 →116.1 for ethambutol, 124.1 → 81.1 for pyrazinamide and 152.0 → 110.0 for 4-acetamidophenol. Each analysis was completed within 5 min. Results Chromatograms showed no endogenous interfering peaks with blank samples. The linear calibration curve was obtained over the concentration on range of 0.1 - 6.0 μ g. ML^-1 for isoniazid and the limit of quantification was 0.1 μg . ML ^-1, 0.1- 5.0 μg . ML^-1 for ethambutol and the limit of quantification was 0.1 μ g . ML^-1, 1.0 - 50.0 μg . ML^-1 for pyrazinamide and the limit of quantification was 1.0 μ g. ML ^-1. The inter and intra-day precision(RSD) was less than 10%. The accuracy was 90.4 - 108.7%. Conclusion The method is specific, sensitive and accurate, and proved to be suitable for the determination of isoniazid, ethambutol, pyrazinamide in human plasma in clinical plasma samples.

关 键 词:异烟肼 乙胺丁醇 吡嗪酰胺 高效液相色谱串联质谱 人血浆 血药浓度 

分 类 号:R978.61[医药卫生—药品]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象