压缩机级间冷却器内漏问题分析  

Analysis of Internal Leakage Problem in Interstage cooler of Compressor

在线阅读下载全文

作  者:刘智广[1] 李芳[2] 

机构地区:[1]新疆油田油气储运公司,新疆克拉玛依834000 [2]东北石油大学,黑龙江大庆163318

出  处:《压缩机技术》2013年第2期36-37,41,共3页Compressor Technology

摘  要:针对大庆油田天然气分公司北压浅冷装置中,3台4RDS型往复压缩机级间冷却器存在着严重的内漏问题,结合现场情况对该冷却器进行了结构分析,找出了冷却器内漏的原因并提出解决问题的建议,减少装置以后再出现类似情况的可能性,以保证装置正常运行。Aiming at the serious internal leakage problem in interstage cooler of the 3 sets 4RDS type reciprocating compressors in Daqing Oil Field Natural Gas Company Branch north pressed shallow cold installment, the strcture of this cooler is analyzed in this paper combined with site condition, and the reason of internal leakage of cooler is found and the suggestion for solving the problem is pointed out.It is helpful for reducing the possibility of similar situation appeared again in devices and has ensured the normal opera- tion of device.

关 键 词:压缩机 冷却器 内漏 结构分析 

分 类 号:TH457[机械工程—机械制造及自动化] TH414.2

 