生物滴滤塔净化甲苯启动性能研究  被引量:4

Start-up performance of biotrickling filter with fungi for toluene purification

在线阅读下载全文

作  者:张会来[1] 王丽萍[1] 李育松[1] 李杰[1] 李江[1] 

机构地区:[1]中国矿业大学环境与测绘学院,徐州221116

出  处:《环境工程学报》2013年第5期1889-1893,共5页Chinese Journal of Environmental Engineering

基  金:江苏省省级环保科技项目(201111)

摘  要:研究以甲苯为驯导物的生物滴滤塔挂膜启动阶段净化性能的变化。实验结果表明,通过控制pH和湿度得到了真菌滴滤系统,启动周期为14 d,比细菌滴滤塔长7 d;在进化性能方面,在入口负荷、浓度为80 g/(m3.h)、3 000 mg/m3的条件下获得了稳定在98%以上的去除效率;对比2种填料对启动阶段的影响,在较低负荷下(≤80 g/(m3.h))对系统的启动时间和去除效率没有显著影响。The elimination capacities of a fungi biotrickling filter in the start-up periods were researched in this study. The experimental results show that the start-up of fungi biotrickling filter needed more time of 14 days comparing with 7 days of bacteria using the same start-up method. Biotrickling filter achieved removal efficiency of 98% with inlet toluene load 80 g/(m^3 · h) and inlet concentration of 3 000 mg/m^3. Elimination capacities and acclimation time had not a significant difference between bacteria and fungi biotrickling filter at a low inlet load.

关 键 词:真菌滴滤塔 陶瓷拉西环 陶粒 启动周期 去除能力 