±1200kV标准直流分压器设计及测量不确定度评定  被引量:11

±1 200 kV Standard DC Voltage Divider Design and the Uncertainty of Evaluation for Measurement

在线阅读下载全文

作  者:袁渊[1] 任稳柱[1] 李平 冯建强[1] 姜宁[1] 谢婷婷[1] 

机构地区:[1]西安高压电器研究院有限责任公司,西安710077 [2]甘肃电器科学研究院,天水741018

出  处:《高压电器》2013年第5期12-17,20,共7页High Voltage Apparatus

摘  要:为满足特高压直流输电工程用直流分压器的校准需求,研制了一台±1 200 kV标准直流分压器。在设计制造过程中,通过电场仿真优化了分压器的结构和屏蔽环的设计,分压电阻采用特殊的屏蔽结构减小了泄漏电流和电容电流的影响,然后对标准分压器进行了量值溯源并进行了国内比对,依据不确定度的评定方法分析了测量不确度分量,给出了总测量不确定度。The ±1 200 kV standard DC voltage divider is developed for calibration of the DC voltage divider in UHVDC transmission project. During the design and manufacture, through electric field simulation, the divider's designs of structure and shield ring are optimized. The special shield structure of dividing resistors can reduce the effects of leakage current and capacitance current. Then, the results of the traceability and the comparison of the standard voltage divider are obtained. Based on the assessment of the uncertainty analysis of the measurement uncertainty component, the total measurement uncertainty is given.

关 键 词:标准直流分压器 电场仿真 屏蔽结构 测量不确定度 

分 类 号:TM933.213[电气工程—电力电子与电力传动]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象