Fe_3O_4/纳米级Fe^0去除水中Cr(Ⅵ)的研究  被引量:2

Study on the Removal of Cr(Ⅵ) by Fe_3O_4/nanoscale Zero-valent Iron(Fe^0) in Wastewater

在线阅读下载全文

作  者:王宁[1] 沈珍秒[1] 施惠芳[1] 张珍[1] 

机构地区:[1]台州学院生命科学学院,台州318000

出  处:《科学技术与工程》2013年第13期3681-3685,共5页Science Technology and Engineering

基  金:国家自然科学基金项目(21107079);浙江省自然科学基金项目(LY12B07003);浙江省科技计划项目(2012C23061)资助

摘  要:考察了Fe3O4/纳米级Fe0对污染水中Cr(Ⅵ)的去除效果,以及Fe3O4投加量、腐殖酸投加量、温度对Fe3O4/纳米级Fe0去除水中Cr(Ⅵ)的影响。结果表明:Fe3O4/纳米级Fe0对水中Cr(Ⅵ)的去除效果很好,在2 min时Cr(Ⅵ)的去除率就能够达到91.4%;这个值比纳米级Fe0单独作用120 min时对Cr(Ⅵ)的去除率还要高。Fe3O4与纳米级Fe0的配比为7.5:1时,Fe3O4/纳米级Fe0对Cr(Ⅵ)的去除效果最好。温度的升高加速了Fe3O4/纳米级Fe0对水中Cr(Ⅵ)还原降解反应的进行。The removal of Cr(VI) by Fe3O4/nanoscale Fe0 and the effect of Fe304 dosage, HA dosage and temperature on it were evaluated. The experiment results indicated that 91.4% Cr(VI) could be removed by Fe3 O4/nanoscale Fe0 within 2 min compared with 5.1% by bare Fe3O4 and 79.0% by bare nanoscale Fe0. And the optimal ratio of F3O4 to nanoscale Fe0 mass lies at 7.5.1. High temperature could increase the Cr(VI) remov- al efficiency.

关 键 词:FE3O4 纳米级Fe. CR(VI) 温度 