常温中和铁氧体法处理高浓度含铜废水的研究  被引量:12

Treatment of high-concentration copper-containing wastewater by room temperature neutralization ferrite process

在线阅读下载全文

作  者:段睿[1] 王立和[1] 杨翠英[1] 寇小燕[1] 

机构地区:[1]山东科技大学化学与环境工程学院,山东青岛266590

出  处:《工业水处理》2013年第5期53-56,共4页Industrial Water Treatment

摘  要:通过实验研究了铁氧体法处理高浓度含铜废水的工艺条件。结果表明:在pH=10.0、n(Fe2+)∶n(Cu2+)=10、n(Fe3+)∶n(Fe2+)=1.5∶1、反应温度为30℃、搅拌时间为15 min的条件下,处理效果最佳。铜的去除率可达99.95%左右,处理后的废水中的Cu2+可从1 600 mg/L左右降至1 mg/L以下,达到GB 25467—2010的间接排放标准。对沉淀进行酸洗、水洗和干燥处理,EDS和XRD分析结果显示在此条件下能生成稳定存在的铜铁氧体。The technological conditions for the treatment of highly concentrated Cu^2+containing wastewater by ferrite process have been studied through experiments. The results show that the best treatment efficiency is achieved under the following conditions : pH = 10.0, n (Fe^2+ ) :n (Cu^2+ ) = 10, n (Fe^2+) :rt (Fe^2+) =1.5:1, reaction temperature =30 ℃ and stirring time=15 min. The highest copper removing rate is around 99.95% and the concentration of Cu^2+ in the treated water is reduced from about 1 600 mg/L to less than 1 mg/L, reaching the indirect discharge standard stipulated in GB 25467--2010. EDS and XRD analyses show that after precipitation has been treated by pickling,washing and drying, stable copper ferrite generates under such conditions.

关 键 词:铁氧体法 含铜废水 沉淀法 

分 类 号:X703[环境科学与工程—环境工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象