检索规则说明:AND代表“并且”;OR代表“或者”;NOT代表“不包含”;(注意必须大写,运算符两边需空一格)
检 索 范 例 :范例一: (K=图书馆学 OR K=情报学) AND A=范并思 范例二:J=计算机应用与软件 AND (U=C++ OR U=Basic) NOT M=Visual
作 者:王为术[1] 李帅帅[1] 王纪宏 杨智峰[3] 赵鹏飞[1]
机构地区:[1]华北水利水电学院 [2]大唐林州热电有限责任公司 [3]三门峡华阳发电有限责任公司
出 处:《电站系统工程》2013年第3期5-8,共4页Power System Engineering
基 金:河南省教育厅自然科学项目(2011A470007)
摘 要:膜式水冷壁温度一直是影响超临界压力锅炉安全的重要部分,采用有限容积法对2690t/h超临界压力锅炉膜式水冷壁温度特性进行数值计算,得出了螺旋管圈水冷壁工质温度、焓值及壁温分布。研究结果表明:随着锅炉负荷的升高,管壁最高温度及最大温差均增大,且最高温度由水冷壁向火侧转移到鳍端,最高温度均低于金属许用温度。在炉膛宽度上,各管间水冷壁温度及工质温度差均很小,螺旋管圈可以有效消除热偏差。In the factors influencing the secure operation of supercritical pressure boilers, the temperature of membrane water-walls is always an important one. Numerical calculations of water-wall temperature profile of the 2690t/h supercritical boiler were conducted using the Finite Volume Method, and the temperature of spiral membrane water-wall and the working medium and enthalpy were obtained. According to the calculating results, both the highest temperature and the maximum temperature difference increase with increasing the furnace load, and the highest temperature, which firstly occurs at the facing flame outer of water wall tube and then appears at the fin's end, does not exceed the permitted value of the metal. As the thermal deviation can be effectively reduced by spiral water-wall, the temperature of water-walls and the temperature difference of working medium between each tube are very small along the width direction of the furnace.
分 类 号:TK16[动力工程及工程热物理—热能工程]