Separation of substituted phenylpiperazine derivatives with immobilized polysaccharide-based chiral stationary phases by supercritical and subcritical fluid chromatography  

键合型多糖手性固定相超临界流体色谱用于取代苯基哌嗪衍生物的拆分(英文)

在线阅读下载全文

作  者:黄珺珺[1] 袁牧[1] 

机构地区:[1]广州医学院药物研究中心,广东广州510182

出  处:《Journal of Chinese Pharmaceutical Sciences》2013年第3期244-251,共8页中国药学(英文版)

基  金:Science and Technology Program of Guangzhou City(Grant No.2010U1-E0531-2)

摘  要:Six newly synthesized racemic 1-(substituted phenyl)-4-[3-(indole-4-yl-oxy)-2-hydroxypropyl]-piperazine 1-6 were successfully resolved by carbon dioxide supercritical fluid chromatography (SFC) on an analytical scale column packed with immobilized polysaccharide-based chiral stationary phases (CSPs). We found that separation on the Chiralpak IA CSP was superior to the other two immobilized CSPs (Chiralpak IB and Chiralpak IC), and isopropanol (IPA) was a superior modifier compared to the other five solvents including ethanol, methanol, tetrahydrofuran, acetonitrile and dichloromethane. The effects of organic modifier composition, back pressure, and column temperature for enantioseparation of all six compounds were studied. Of the physical parameters studied, modifier composition had the greatest impact on retention. Changing temperature generally had less impact on retention but produced the greatest selectivity changes. The optimum condition was found as follows: Chiralpak IA column, column temperature 35 ~C, back pressure 120 bar, 35% IPA containing 0.1% diethylamine (v/v) in mobile phase, flow rate of mobile phase 3.0 mL/min, UV detection 283 nm. Separation of all six racemic compounds was completed within 10 rain and excellent resolution was obtained. Thus, SFC was found to be the methodology of choice for resolving the enantiomers of this class of compounds.合成了六个新型的1-取代苯基-4-[3-(吲哚-4-氧基)-2-羟丙基]-哌嗪消旋体化合物1–6,并利用键合型多糖手性固定相超临界流体色谱完成了对其的手性拆分研究。实验表明,基于固定相Chiralpak ⅠA的拆分优于其它两种键合型固定相(Chiralpak ⅠB、Chiralpak ⅠC),改性剂异丙醇的效果优于乙醇、甲醇、四氢呋喃、乙腈、二氯甲烷。本文还研究了有机改性剂、背压与柱温对六个化合物对映体拆分的影响。结果表明,改性剂组成最大程度地影响了分离时间,柱温的改变对分离时间的影响较小但最大程度地影响了对映体选择性的变化。最优的拆分条件为:固定相为Chiralpak ⅠA柱,柱温为35℃,背压为120bar,流动相为35%异丙醇(含0.1%二乙胺),流速为3.0mL/min,紫外检测波长为283nm。该六个消旋体化合物在10分钟内得到了良好的拆分。超临界流体色谱法是拆分该类化合物对映体的有效方法。

关 键 词:Supercritical fluid chromatography Immobilized polysaccharide-based chiral stationary phases Enantiomerresolution Phenylpiperazine derivatives 

分 类 号:TQ463.5[化学工程—制药化工]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象