作 者:汤效飞[1] 张满霞[1] 李群生[1] 文放[1] 李仑[1]
出 处:《北京化工大学学报(自然科学版)》2013年第3期21-26,共6页Journal of Beijing University of Chemical Technology(Natural Science Edition)
基 金:中国石化股份有限公司资助项目(X501021)
摘 要:设计了一种新型塔板,即导向筛板-新型浮片式浮阀复合塔板,并在内径Φ600的有机玻璃塔内以空气-水为物系,对该复合塔板进行了冷模实验。测定了不同开孔率的复合塔板在固定堰高,改变气速和液流强度情况下的塔板压降、雾沫夹带率、漏液率和清液层高度,并与相同实验条件下的F1型浮阀塔板的流体力学参数进行了对比。此外,本文采用氧解析实验对新型塔板的传质性能进行了研究。实验结果表明,导向筛板-新型浮片式浮阀复合塔板相比F1型浮阀具有通量大、压降低、抗堵性好、传质效率高和浮阀不易卡死、脱落等优点。实验数据表明,该复合塔板的干板压降、湿板压降和雾沫夹带率都随着孔动能因子和液流强度的增大而增大;漏液率随着孔动能因子的增大而减小,随着液流强度的增大而增大;传质效率随着孔动能因子的增大而增大,随着液流强度的增大而减小;清液层高度随着孔动能因子的增大呈现上升、稳定然后下降的趋势,并且随着液流强度的增大而增大。根据实验数据,回归得到了该复合塔板的干板压降(Δpd=aF20+b)、湿板压降(ΔpT=ξF0mLnW)和雾沫夹带率(eV=aF0mLnW)的关联式。A new tray composed of a new floating roundel valve and a flow-guided sieve tray(GS-FRV) has been designed,and cold-flow model experiments for the trays have been conducted in a Φ600 mm perspex column with an air-water system.GS-FRV trays with different aperture ratios and F1 floating valve trays were studied.The efficiency performance and hydromechanics of GS-FRV trays have been measured for different air velocities and flow intensities and the results contrasted with those for F1 floating valve trays measured under the same conditions.The experimental results show that the GS-FRV trays have higher capacity,lower pressure drop,better anti-clogging behavior and are less prone to seizure compared with F1 floating valves.The GS-FRV trays also show high efficiency performance.Experimental data show that: the plate pressure drop and entrainment rate increase with the increase of the kinetic energy factor(F-factor) and liquid flow intensity;the weeping rate decreases with the increase of the F-factor and increases with the increase of the liquid flow intensity;the efficiency performance increases with the increase of the F-factor and decreases with the increase of the liquid flow intensity;the clear liquid height first increases,then stabilizes and finally decreases with the increase of the F-factor and decreases with the increase of the liquid flow intensity.According to the experimental data,the regression formulae of the dry plate pressure drop(Δpd=aF20+b),the wet plate pressure drop(ΔpT=ξFm0LnW) and the entrainment rate(eV=aFm0LnW) for the GS-FRV have been derived,and the variation of entrainment rate,weeping rate and clear liquid height as a function of changing F0 and flow intensity have been obtained.
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在载入数据...
正在链接到云南高校图书馆文献保障联盟下载...
云南高校图书馆联盟文献共享服务平台 版权所有©
您的IP:216.73.216.69