摘 要:从效率角度出发研究了非接触电能传输系统负载对副边补偿结构选择的影响,得出了效率边界负载,为副边选取合适的补偿结构提供了依据;从稳定性角度出发研究了负载与频率分叉之间的关系,得出了稳定性边界负载。在既保证效率又保证稳定性的条件下,得出了负载的运行范围。From the point of efficiency, the effects of contactless electrical power transmission system load on the choice of compensation structure in secondary were researched. Then, the boundary load conditions of efficiency were drawn, which provides a basis for choosing the suitable compensation structure in secondary. From the point of stability, the relationships between load and frequency bifurcation was researched and the boundary load conditions of stability were drawn. Under the conditions of making sure of the efficiency and stability, the load operating ranges were given.