摘  要:介绍了临界装置功率刻度的方法,在不同功率台阶下利用活化法测量临界装置的中子注量率分布及归一点的绝对中子注量率,并利用经修改编译的MCNP程序对临界装置的中子注量率分布进行校核计算。基于中子注量率测量及计算结果通过裂变率法计算不同功率台阶下临界装置的功率,同时外推到堆芯最大热中子注量率为1×108 cm-2.s-1时的功率,实现了临界装置的功率刻度。The method for power confirming was introduced.Neutron fluence rate distribution and absolute neutron fluence rate of one point for critical facility under different powers were measured by activation method.Neutron fluence rate distribution was calculated with compiled MCNP code.The power of critical facility was calculated with fission rate method based on neutron fluence rate.The power was extrapolated while the max thermal neutron fluence rate was 1×108 cm-2·s-1.The power confirming for critical facility was completed.