作 者:Jiaqing ZHANG Shouxiang LU Qiang LI Changhai LI Man YUAN Richard YUEN
机构地区:[1]State Key Laboratory of Fire Science, University of Science and Technology of China [2]Department of Civil and Architectural Engineering, City University of Hong Kong [3]USTC-CityU Joint Advanced Research Centre
出 处:《Journal of Thermal Science》2013年第4期377-382,共6页热科学学报(英文版)
基 金:supported by National Natural Science Foundation of China (Project no. 50976109 and no. 51206157);the Research Fund for the Doctoral Program of Higher Education of China (Grant no. 20123402110048);a Grant from CityU (Project No. 7002577)
摘 要:The impacts of elevation on fires in a ceiling vented compartment were investigated experimentally. The flame behavior of elevated fires was recorded. Various parameters including the fuel mass loss rate, the light extinction coefficient, the oxygen concentration and the gas temperature were measured. Results indicated that the variations of the flame behavior were consistent with that of the fuel mass loss rate. The fire location significantly impacted the light extinction coefficient, the oxygen concentration and the gas temperature, which all showed distinct stratification phenomena. For a higher elevated f'we, the average fuel loss rate and the overall light extinction co- efficient were smaller, the oxygen concentration was higher and the gas temperature was lower. In addition, the smoke descending was slower. From the perspective of those parameters the fire was less hazardous if the fire was elevated higher, which was totally different from the elevated fires in closed compartments.
关 键 词:Compartment fire Ceiling vent Elevated fires Fire hazard
分 类 号:TU201[建筑科学—建筑设计及理论] TU998.1