JX-300XP系统在“三废”余热锅炉中的应用  

JX-300XP DCS application in waste heat boiler

在线阅读下载全文

作  者:郑建章 

机构地区:[1]福建省顺昌富宝实业有限公司,福建顺昌353205

出  处:《低碳世界》2013年第02X期98-101,共4页Low Carbon World

摘  要:本文主要介绍了JX-300XPDCS控制系统在"三废"混燃炉上的应用。首先介绍了"三废"混燃炉特点及JX-300XP系统的优点,然后在此基础上对系统硬件、软件设计,选型与配置,组态设置及实时监控等进行了深入探讨,最后结合混燃炉,从而验证JX-300XP系统能够有效地降低劳动强度,并实现锅炉燃烧的完全自控,确保锅炉安全可靠地运行。The paper briefly introduces JX-300 XP DCS control system used in "three wastes" mix burning furnace. First we intro- duced the performance of "three wastes" mix burning furnace and JX-30OXP system, then we further discussed the design of system hardware and software, selection and configuration and configuration Settings and real-time monitoring. Based on the application in mix burning furnace, JX-300 XP system can effectively reduce the labor intensity, and realize the boiler burning fully automatic control and ensure system can run safely and reliably.

关 键 词:混燃炉 JX-300XP系统 可靠运行 

分 类 号:TK229.929[动力工程及工程热物理—动力机械及工程]

 