出  处:《腐蚀与防护》2013年第7期635-637,共3页Corrosion & Protection

摘  要:提出了在设计和实施阴极保护过程中经常遇到的七个方面的误区:阴极保护方法的选择;外加电流法的电源装置的选用;牺牲阳极数量;绝缘接头(或绝缘法兰)数量;阳极材料的选择;阴极保护电位的测量方法;阴极保护电位是否达到或比-0.85V(CSE)更负就放心了。以期在今后设计和实施中不断提高阴极保护水平。There are seven common mistakes in the following aspects clurmg the design and impiementaton of cathodic protection: (1) Selection of cathodic protection methods; (2) Selection of the power supply apparatus in the impressed current method; (3) Number of anodes; (4) Number of insulating joints (or insulating flanges); (5) Selection of anodic materials; (6) Measurement method of proection potential ; (7) Whether the cathodic protection potential equal to or lower than -0. 85 V (CSE) will be completely safe. Better understanding them will help to improve cathodic protection in the future work.

关 键 词:阴极保护 阴极保护施工 阴极保护中的误区 

分 类 号:TG174.41[金属学及工艺—金属表面处理]

 