AAS和ICP-OES测定涂料中“铅(Pb)”含量的比较  被引量:3

The Comparation of Determination of the Lead Content in Coatings with AAS and ICP-OES Instrument

在线阅读下载全文

作  者:张永刚[1] 万雪期[1] 黄宁[1] 

机构地区:[1]中海油常州涂料化工研究院检测中心,江苏常州213016

出  处:《上海涂料》2013年第6期44-48,共5页Shanghai Coatings

摘  要:通过制备干漆膜,采用AAS(原子吸收光谱仪)和ICP-OES(电感耦合等离子体发射光谱仪)分别测定了内墙涂料、聚氨酯色漆和聚氨酯清漆中的可溶性铅含量。通过直接称样,再使用盐酸溶液溶解、定容,测定了环氧富锌底漆用锌粉中的总铅含量。比较了这两种仪器的测定结果,讨论了结果差异的形成原因。The soluble lead content of the dry film of interior wall coatings, polyurethane paint and varnish were tested using AAS and ICP-OES instrument respectively. The total lead content of the zinc powder in the epoxy zinc- rich primer were tested after weighting, dissolving with hydrochloric acid solution, constanting volume. The test results of using AAS and ICP-OES respectively were compared. The differences were found out, and the causes of differences were discussed.

关 键 词:涂料 铅含量 测试结果 AAS ICP—OES 

分 类 号:TQ630.7[化学工程—精细化工] O657.3[理学—分析化学]

 