燃气-蒸汽联合循环机组余热锅炉安全门整定中旁路超温的问题分析  

Analysis of Problem on Bypass Overheating of Heat Recovery Steam Generator of Gas-steam Combined Cycle Unit during Safety Valve Setting Test

在线阅读下载全文

作  者:吴锋[1] 赵熙[1] 司派友[1] 毛永清[1] 张清峰[1] 章嵛耑 张晓红 

机构地区:[1]华北电力科学研究院有限责任公司,北京100045 [2]北京京桥热电有限责任公司,北京100011 [3]中机国能电力工程有限公司,上海200061

出  处:《华北电力技术》2013年第7期26-29,37,共5页North China Electric Power

摘  要:介绍了北京京桥热电厂的燃气-蒸汽联合循环机组及其余热锅炉的热力系统。分析了该机组余热锅炉安全门整定期间低压旁路蒸汽超温的问题,并给出了试验期间的解决方案。同时,讨论了该问题在机组正常运行时存在的可能性以及相应的技改措施。This paper introduces the gas-steam combined cycle unit in Beijing Caoqiao thermal power plant and the heating system of it's Heat Recovery Steam Generator (HRSG) , analyzes the over-temperature problem of low-pressure steam bypass during the unit HRSG safety valve setting, and gives the solution during the test. At the same time, it discussed the existence possibility of this problem during normal operation of the unit, and the corresponding improvement measure.

关 键 词:燃气-蒸汽联合循环 余热锅炉 安全门整定 旁路 超温 

分 类 号:TM611.31[电气工程—电力系统及自动化]

 