包钢加固管道支架的整体性能分析  

Whole performance analysis of steel-encased pipe racks

在线阅读下载全文

作  者:郝聪[1] 魏翠玲[1] 

机构地区:[1]河北工程大学土木工程学院,河北邯郸056038

出  处:《河北工程大学学报(自然科学版)》2013年第2期12-15,共4页Journal of Hebei University of Engineering:Natural Science Edition

摘  要:考虑加固后的管道支架参与整体受力,采用有限元软件对加固管架进行整体模拟,对比分析采用外包钢加固管道支架单片平面框架计算模型和采用相同结构特征的整体计算模型的承载力值。分析表明:管道参与整体受力,加固后的管道支架整体受力比单片平面框架计算值较小,且靠近固定管架的加固支架差值较大,可适当减小该处加固型钢截面,以减少用钢量。Considering that the reinforced pipe rack participates in the overall force,the overall reinforcement pipe rack was simulated by using the finite element software,the bearing capacity of the model of monolithic plane frame and the overall calculation model using the same structural characteristics were analyzed.The results showed pipeline involved in the overall force,the overall support force value of reinforced pipe was smaller than the monolithic planar frame calculation,and the difference value of reinforced rack closer to fixed tube frame was small.In order to reduce the amount of steel,we may reduce appropriately its reinforcement steel sections.

关 键 词:外包钢 支架 有限元 承载力 

分 类 号:TU398.9[建筑科学—结构工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象