非破坏法与干燥器法测定木地板甲醛释放量比对研究  被引量:1

Determination of formaldehyde emission for wood flooring with non-destructive method and dryer

在线阅读下载全文

作  者:俞凌云[1,2] 温演庆[1] 韩松[1] 罗杨[1] 胡世强[1] 杨洁[1] 李东[1] 

机构地区:[1]四川出入境检验检疫局,四川成都610041 [2]四川大学高分子科学与工程学院,四川成都610065

出  处:《中国测试》2013年第4期48-51,共4页China Measurement & Test

基  金:国家质检总局基金项目(2009IK291)

摘  要:为省去木地板甲醛释放量测定之前锯板封边操作,减少准备试件的偶然误差,更加真实地反映室内木地板甲醛的自然释放量,以"干燥器法"为基础,研究设计模拟干燥器的非破坏木地板甲醛释放量装置,建立非破坏法测定木地板甲醛的方法。经过比对测试,非破坏法甲醛释放量低于干燥器法,但趋势一致;两种方法具有相关性,其比值为1.44左右。自制的非破坏木地板甲醛释放量装置测试木地板甲醛释放量,达到了非破坏的目的,可以与干燥器法甲醛释放量测定结果相互转化。Taking "dryer method" as the foundation, the authors designed a non-destructive wood flooring formaldehyde releases device and established a non-destructive method. This method could cut down the process of board side sealing before determination of wood flooring formaldehyde, and reduce the accidental errors caused by specimen preparation, which could more truly reflect the formaldehyde release of artificial floor in the indoor air. The comparison experimental results show the formaldehyde release determined by non-destructive method proposed in this paper is lower than but relative to that by the drying apparatus method, the ratio is about 1.44, and the trends are consistently. The results of the two methods are mutually transformational. Thus, the non-destructive method can test the formaldehyde releases of wooden floor without destroy.

关 键 词:木地板 甲醛 非破坏法 干燥器法 释放量 

分 类 号:TQ351.275[化学工程] X502[环境科学与工程—环境工程]

 

参考文献:

正在载入数据...

 

二级参考文献:

正在载入数据...

 

耦合文献:

正在载入数据...

 

引证文献:

正在载入数据...

 

二级引证文献:

正在载入数据...

 

同被引文献:

正在载入数据...

 

相关期刊文献:

正在载入数据...

相关的主题
相关的作者对象
相关的机构对象