工业废水中苯胺类化合物的测定研究  被引量:2

Study on the Determination of Anilines in Industrial Waste Water

在线阅读下载全文

作  者:林海吟 

机构地区:[1]惠州市惠城区环境保护监测站,广东惠州516001

出  处:《广东化工》2013年第13期192-193,共2页Guangdong Chemical Industry

摘  要:文章应用国际经典分析方法 N-(1-萘基)乙二胺偶氮光度法(GB/T11889-1989)对废水中苯胺类化合物进行了探索性测定分析。实验结果表明,显色温度在25℃,显色时间为40 min,调节pH的硫酸氢钾滴加量为0.6 mL,重氮化时间为3 min,能够确保水样苯胺类化合物测定的精密度和准确度。通过进一步的标样分析,该实验条件下精密度为1.12%~1.35%,加标回收率为98.82%~100.59%之间。The paper application of analysis method of N international classic-(1-naphthyl) ethylenediamine azo spectrophotometry(GB/T11889-1989) was studied on determination of aniline compounds in waste water.The experimental results show that,the color temperature at 25 ℃,chromogenic time is 40 min,potassium bisulfate amount regulating pH 0.6 mL,diazotization time is 3 min,to ensure that the determination of aniline compounds of precision and accuracy.Through further analysis of the samples,the experimental conditions of fine density is 1.12 %~1.35 %,the recovery is 98.82 %~100.59 %.

关 键 词:苯胺类化合物 测定 去干扰试验 N-(1-萘基)乙二胺偶氮光度法 

分 类 号:X5[环境科学与工程—环境工程]

 