活性碳吸附-气相色谱法测定空气和废气中的乙酸  被引量:3

GC Determination of Acetic Acid in Ambient Air and Exhaust Gas by Adsorption in Activated Carbon Tube

在线阅读下载全文

作  者:仲维斌 宋晓娟 马玉琴 

机构地区:[1]连云港市环境监测中心站,江苏连云港222001

出  处:《污染防治技术》2013年第3期73-74,79,共3页Pollution Control Technology

摘  要:该研究建立了活性碳管吸附-甲酸溶剂解析-气相色谱法测定环境空气和废气中乙酸的方法,当采样量为30L时,方法检出限为:0.015 mg/m3,加标回收率为90.3~92.6%,相对标准偏差为0.94~1.25%。方法简单、灵敏度高、分离度好、干扰少、检出限低。Acetic acid in ambient air and exhaust gas was determined by Gas chromatography in this study.Acetic acid was firstly adsorbed in activated carbon tubes and then desorbed with formic acid.With sampling volume 30 liters,the detection limit for acetic acid were 0.015 mg / m^3.The recoveries with standard addition ranged from 90.3% to 92.6%.Relative standard deviation(RSD) ranged from 0.94% to 1.25%.This method was simple and accurate,and had a high resolution and low dection limit.

关 键 词:气相色谱法 活性碳管 乙酸 甲酸 FID检测器 

分 类 号:X831[环境科学与工程—环境工程]

 